FlashArray//m Technical Specs

Flash Array//m front bezel view
//m Bezel
Flash Array//m front exposed view
//m Front View
Flash Array//m back panel view
//m Back View
 

//m20

//m50

//m70


System
Performance

  • Up to 150,000 32K IOPS @
    < 1ms average latency
  • Up to 5 GB/s bandwidth
  • Up to 220,000 32K IOPS @
    < 1ms average latency
  • Up to 7 GB/s bandwidth
  • Up to 300,000 32K IOPS @
    < 1ms average latency
  • Up to 9 GB/s bandwidth

Why does Pure Storage quote 32K, not 4K IOPS?
The industry commonly markets 4K IOPS benchmark to make numbers look high, but real-world environments are dominated by IO sizes of 32K or larger. Pure Storage has optimized the FlashArray for the real-world. FlashArray adapts automatically to 512B- 32KB IO for superior performance, scalability, and data reduction.
 

//m20

//m50

//m70


System Capacity

  • //m20
    15 – 120+ TBs in 3U
  • bezel
  • //m50
    90 - 120 TBs in 3U
  • bezel
  • //m70
    150 TBs in 5U
  • bezelFlash Array//m front exposed view
 
  • Scaled //m50
    Up to 250+ TBs in 7U
  • bezelFlash Array//m front exposed viewFlash Array//m front exposed view
  • Scaled //m70
    Up to 400+ TBs in 11U
  • bezelFlash Array//m front exposed viewFlash Array//m front exposed viewFlash Array//m front exposed viewFlash Array//m front exposed view
  • 5 – 40 TBs raw capacity
  • 30 - 88 TBs raw capacity
  • 44 – 136 TBs raw capacity

Displayed capacity is effective capacity, unless otherwise noted. Effective capacity assumes HA, RAID, and metadata overhead, GB-to-GiB conversion, and includes the benefit of data reduction with always-on & global inline deduplication, compression, deep reduction, and pattern removal. Average data reduction is calculated at 5-to-1. Some customers see data reduction in excess of 20-to-1. Effective capacity has no upper limit and will vary depending on workload.

Capacity is purchased and added in capacity packs of 10 x Flash Modules. Three options are available: 5TB, 10TB, and 20TB. Capacity packs can be mixed within an //m system.

//m20 can be expanded beyond the 3U base chassis with expansion shelves.

 

//m20

//m50

//m70


System NV-RAM

  • 2 x 8 GB NVRAM Modules
  • 2 x 8 GB NVRAM Modules
  • 4 x 8 GB NVRAM Modules

NV-RAM specifications are calculated per //m system
 

//m20

//m50

//m70


System Size,
Power and Weight

  • 3U*
  • 742 Watts (Nominal)
  • 80 pounds**, 105 pounds***,
    110 pounds ****
  • 5.12" h x 18.94" w (including rack ears) x 29.72" d FlashArray//m chassis
  • 3U – 7U
  • 1007 - 1447 Watts (Nominal)
  • 80 pounds**, 105 pounds***, 110 pounds **** + 44 lbs per expansion shelf
  • 5.12" h x 18.94" w (including rack ears) x 29.72" d FlashArray//m chassis
  • 5U – 11U
  • 1439 - 2099 Watts (Nominal)
  • 80 pounds**, 107 pounds***, 112 pounds **** + 44 lbs per expansion shelf
  • 5.12" h x 18.94" w (including rack ears) x 29.72" d FlashArray//m chassis

* //m20 can be expanded beyond the 3U base chassis with expansion shelves.

** Unloaded //m system without NV-RAM Modules, Flash Modules, or Blank Carriers

*** //m system with 2 x NV-RAM Modules, 10 x Flash Modules, 10 x Blank Carriers, and Bezel

**** //m system with 2 x NV-RAM Modules, 20 x Flash Modules, and Bezel

 

//m20

//m50

//m70


Connectivity
Specificiations

Onboard IO


  • 4 x 10Gb/s Ethernet
    (iSCSI or Replication ports)
  • 4 x 1Gb/s Ethernet (Management ports)
  • 8 x 12 Gb/s SAS ports
  • 4 x 10Gb/s Ethernet
    (iSCSI or Replication ports)
  • 4 x 1Gb/s Ethernet (Management ports)
  • 8 x 12 Gb/s SAS ports
  • 4 x 10Gb/s Ethernet
    (iSCSI or Replication ports)
  • 4 x 1Gb/s Ethernet (Management ports)
  • 8 x 12 Gb/s SAS ports

Configurable IO


  • 6 IO slots
  • 2-port 8Gb/s Fibre Channel
    or 2-port 10Gb/s Ethernet iSCSI IO Modules
  • Mix and Match
  • 6 IO slots
  • 2-port 16Gb/s Fibre Channel, or 2-port 10Gb/s Ethernet iSCSI IO Modules
  • Mix and Match
  • 6 IO slots
  • 2-port 16Gb/s Fibre Channel, or 2-port 10Gb/s Ethernet iSCSI IO Modules
  • Mix and Match

Host connectivity and ports are calculcated per HA system. The Pure Storage FlashArray serves IO from both active/active controllers
 

//m20

//m50

//m70


Software

  • Purity Operating
    Environment 4.5
  • Purity Operating
    Environment 4.5
  • Purity Operating
    Environment 4.5

Expansion Shelf Specifications

  • 12, or 24 TBs raw capacity
  • 2U
  • 200 Watts
  • 44 pounds per shelf
  • 3.46” h x 19.01” w x 22.71” d
  • bezel
//m Expansion Shelf

Environmental

  • //m20, //m50, //m70
  • RANGE
  • NOTES

  • Operating Temperature
  • 5° to 35° C
  • Derate 1 C per 300 m above 950 m

  • Non-operating Temperature
  • 0° to 60° C
  •  

  • Operating Humidity
  • 10 – 80%
  • Non-condensing

  • Non-operating Humidity
  • 5 – 95%
  • At a maximum temperature of 33° C. Non-condensing, web bulb 33° C.

Regulatory and
Compliance

Electromagnetic Compatibility (EMC)


  • FCC Part 15, Subpart B, Class A, EN 55022, Class A
  • Canada ICES-003, Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, AS/NZS CISPR 22, KN22/KN24, CNS 13438

Safety


  • UL/IEC 60950-1, EN 60950-1, CS Scheme with all country differences.

Certifications / Markings


  • UL/cUL Mark, CE Mark, FCC Class A, ICES-003
  • Class A, VCCI Class A, ACMA RCM, BSMI, KCC